Customization: | Available |
---|---|
After-sales Service: | Provided |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 13800/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power supply: AC220V±10%, frequency: 50HZ±5%;
Working temperature: :25ºC±3ºC.
Humidity: ≤ 85%R.H (non-condensing)
No severe shake, no corrosive gases, no flammable or explosive gases around.
No. | Item | ACEY-ACTS-20V5A-GGS | ||
1 | Main channels | 40Channels (8CH/module) | ||
2 | Channels working mode | Independently | ||
3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
Discharge: CD, CP, CR | ||||
Still | ||||
Ending condition of main channel | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, Temperature (NTC detection temperature and GGS temperature), etc. | |||
4 | Main channel Voltage | Test range of voltage | 0V-20V | |
Min. discharge voltage | 1.5V | |||
Accuracy | ±0.02%FS+0.02%RD(@25±3ºC) | |||
Resolution | 0.1mV | |||
Main channel Current | Test range of current | ±5A | ||
Min. output current | 20mA | |||
Accuracy | ±0.02%FS+0.02%RD(@25±3ºC) | |||
Resolution | 1mA | |||
Current start response time | <10ms | |||
Time | Resolution | 10ms | ||
Power | Output power | Single channel continuous working power 100W | ||
Stability | ±0.05%FS+0.05%RD | |||
Auxiliary channel parameter cutoff function | Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition. | |||
5 | ACTS Communication | LAN | ||
6 | GGS Communication (Optional) | SMBUS, I2C, HDQ | ||
Support reading 100kHz and 400kHz communication frequency battery information (software can be set and switched) | ||||
Support single channel independent operation of different data communication protocols. (If GGS communication and INA231 communication are selected) | ||||
Support multi-channel simultaneous sampling, and the data recording interval of the same channel is ≥ 1s (The same table as the charge and discharge data) | ||||
7 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9,999 | |||
Programmable step | Max. 9,999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Maximum recording time:10ms, voltage≤0.02%FS, current ≤0.02%FS | |||
Program feature | Each step has one or multiple exit | |||
Barcode scan | Support | |||
8 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
9 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
10 | Data saving | Save as files | ||
11 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||
12 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||
Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
13 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||
14 | Energy consumption | Heat dissipation | ||
15 | Cooling method | Forced Fan-cooled | ||
16 | Voice | Less than 70dB(Single set) | ||
IP grade | IP20 | |||
17 | Repair | Modularized structure. Can be replaced or repair with spare parts. |
Cabinet size | 920*722*1805mm |
Weight | ≤300KG |
Channel number | 40CH |
Remarks :The above picture is for reference only, subject to the kind! |