5V 500A 4/10 Channels Li-ion Lead Acid Battery Cell Capacity Grading Machine Cycle Life Test Equipment Lithium Battery Charge Discharge Tester
Working Environment and Technical Parameters
Parameters
No. | Item | ACEY-HRCDS-5V500A | ||
1 | Main channels | 1CH/ module | ||
2 | Channel working mode | Completely independent. | ||
3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. | ||
Discharge: CD, CP, CR, DCCV. | ||||
Still, Pulse test, Working Condition test, DCIR test. | ||||
Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
4 | Main channel Voltage | Single channel test range | 0V-5V | |
Min. discharge voltage | 1V | |||
Accuracy | ±0.05%FS | |||
Resolution | 0.1mV | |||
Main channel Current | Single channel test range | ±500A | ||
Min. output current | 500mA | |||
Accuracy | ±0.05%FS | |||
Resolution | 1mA | |||
Current start response time | <10ms(10%FS~90%FS) | |||
Time | Resolution | 10mS | ||
Auxiliary temperature (Optional) | Range | -20~100 | ||
Accuracy | ±1(0~70) | |||
Resolution | 0.1 | |||
Power | Output power | Single channel continuous working power 2500W | ||
Stability | ±0.1%FS | |||
5 | Communication | LAN | ||
6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9999 | |||
Programmable step | Max. 9999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Time≥10ms,Voltage≥0.05%FS,Current≥0.05%FS | |||
Program feature | Each step has one or multiple exit | |||
7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
9 | Data saving | Save as files | ||
10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. |
Equipment Appearance and Structure
Cabinet size | 600*845*1030mm |
Weight | ≤250KG |
Channels number | 4CHS/10CHS |