Customization: | Available |
---|---|
After-sales Service: | Provided |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 9230/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1-32 Series 200A Charge 200A Discharge Battery Management System Testing Machine BMS Tester Machine
1-32 series power battery protection board tester with high degree of automation, fast testing speed and high testing accuracy. With test overcharge, overcharge recovery, overdischarge, overdischarge recovery, overcurrent (overcharge current and overdischarge current), internal resistance, self-consumption, short-circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection time, equalization current, equalization voltage, 13 performance.
Can meet the current market lithium ternary batteries, lithium iron phosphate batteries and cobalt acid battery protection plate test, with lithium ternary batteries, lithium iron batteries and cobalt acid battery test gear switching function.
The instrument requires connection to a computer, computer hardware configuration requirements for general office computers can be, the system generally requires XP system, the instrument and the computer using industry-standard 232 interface.
1. Input power requirements: 180 ~ 240V 50/60HZ, power: 700W
2. The equipment access to the power requirements of the domestic use of 220V/50HZ alternating current, allow fluctuations in the range of 10% or less.
3. Charging and discharging voltage: 5000mV ~ 160,000mV
4. The equipment can be used to detect and set the voltage range when charging or discharging.
5. Current accuracy: ±(0.1%FS+0.1%RD)
6. When the device detects or sets the current, the error range, i.e. 0.1% of the full scale plus 0.1% of the reading error
7. Voltage accuracy: ± (0.1%FS+0.1%RD)
8. Equipment in the detection or setting voltage, the error range, that is, 0.1% of the full scale plus reading error 0.1%.
9. Current resolution: 1mA, the smallest unit used by the device when detecting or setting current.
10. Voltage resolution: 1mV, the smallest unit used when the device detects or sets the voltage.
11. Cycle: cycle times:1~9999 times
12. Using the programming, the number of times the device carries out an uninterrupted cycle of the various indicators of the protection board.
13. Log tracking
14. With log function, including testing the entire process of operation records, exception records, can be used to test the process of tracing.
15. Data processing, man-machine interface
16. Test data is saved in EXCEL file.
17. The RS232 interface is used for the interface between the device and the upper computer, which can ensure the stability and real-time data acquisition.
18. Accuracy calibration / software calibration
19 with a sweep start function
20.MES system connection
No. | Function | Setting range | Testing accuracy | Unit |
1 | Single section self-consumption | 0--500 | ±0.1 | uA |
2 | Self-consumption | 0--5000 | ±1 | uA |
3 | Overcharge protection voltage | 500--5000 | ±1 | mV |
4 | Overcharge protection release voltage | 500--5000 | ±1 | mV |
5 | Overcharge protection delay time | 0--10000 | ±1 | mS |
6 | Over-discharge protection voltage | 500--5000 | ±1 | mV |
7 | Over-discharge protection release voltage | 500--5000 | ±1 | mV |
8 | Overcharge voltage protection delay time | 0--10000 | ±1 | mS |
9 | Overcharge current protection value | 0.1--200 | ±0.01 | A |
10 | Overcharge current protection delay time | 0--20000 | ±1 | mS |
11 | Overcharge current protection value | 0.1--200 | ±0.01 | A |
12 | Over discharge current protection delay time | 0.1--20000 | ±1 | mS |
13 | Equalizing opening voltage | 500--5000 | ±1 | mV |
14 | Equalizing Current | 1--500 | ±1 | mA |
15 | Charging Aging Current | 0.1--120 | ±0.01 | A |
16 | Discharge Aging Current | 0.1--120 | ±0.01 | A |
17 | Charging aging time | 0--100 | ±1 | S |
18 | Discharge current aging time | 0--100 | ±1 | S |
19 | Single section self-consumption difference | 0-500 | ±0.1 | uA |
20 | Resistance | 0-999 | ±1 | mΩ |
21 | Short circuit protection time | 0--5000 | ±1 | uS |
22 | Charging aging voltage | 500--5000 | ±1 | mV |
23 | Single discharge aging voltage | 500--5000 | ±1 | mV |
24 | Open circuit voltage | 160000 | ±1 | mV |
25 | Number of voltage simulations | 32 | 0 | PCS |