Customization: | Available |
---|---|
After-sales Service: | Provided |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 8900/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
5V 200A 8 Channel Battery Charge Discharge Testing Equipment Lithium Battery Cell Capacity Tester
It is mainly used in life aging test (Circle Life Testing) and quality control in the production or experiment of lithium-ion batteries, lead-acid batteries, cadmium nickel batteries, nickel metal hydride batteries and other batteries.
Supported test content: battery cycle life test, battery capacity test, battery charging characteristic test, battery discharge characteristic test, battery charge holding capacity test, battery charge and discharge efficiency test, battery overcharge, overdischarge rate bearing capacity test, pulse test, working condition test, etc.
Single power supply: AC voltage 220V ± 10%, frequency: 50 Hz ± 5%,
Whole cabinet power supply: AC voltage 380V ± 10%, frequency: 50 Hz ± 5%
Maximum input power of the whole cabinet: 8.8KW (8CH)
Ambient temperature: 0-45
Ambient humidity: not more than 85%R.H (no water vapor condensation)
No strong environmental vibration, no corrosive gas and flammable and explosive gas existence
Resolution: AD: 16bit
No. | Item | ACEY-HRCDS-5V200A-8CH | ||
1 | Main channels | 2CH/ module | ||
2 | Channel working mode | Completely independent. | ||
3 | Main channel working mode | Charge: CC, CV, CP, CCCV, no voltage or current impact when CC transfer to CV. | ||
Discharge: CD, CV, CP, CR, DCCV. | ||||
Rest, Pause, Pulse test (minimum pulse width: 20ms), | ||||
Working Condition test, DCIR test. | ||||
Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
4 | Main channel Voltage | Single channel test range | 0V-5V | |
Min. discharge voltage | 1V | |||
Accuracy | ±0.05%FS | |||
Resolution | 0.1mV | |||
Main channel Current | Single channel test range | ±200A | ||
Min. output current | 200mA | |||
Accuracy | ±0.05%FS | |||
Resolution | 1mA | |||
Current start response time | <10ms(10%FS~90%FS) | |||
Time | Resolution | 10mS | ||
Auxiliary voltage | Range | DC: 0-5V | ||
Accuracy | ±0.05%FS | |||
Resolution | 1mV | |||
Auxiliary temperature | Range | -20~100 | ||
Accuracy | ±1(0~70) | |||
Resolution | 0.1 | |||
Power | Output power | Single channel continuous working power 1000W | ||
Stability | ±0.1%FS | |||
5 | Communication | LAN | ||
6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9999 | |||
Programmable step | Max. 9999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Time≥10ms,Voltage≥0.05%FS,Current≥0.05%FS | |||
Program feature | Each step has one or multiple exit | |||
7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
9 | Data saving | Save as files | ||
10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection. | ||
Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. | |||
Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
14 | Energy consumption | Discharge power feedback to grid | ||
15 | Cooling method | Forced Fan-cooled | ||
Noise | Less than 70dB | |||
IP grade | IP20 | |||
16 | Repair | Modularized structure. Can be replaced or repair with spare parts. |