Customization: | Available |
---|---|
After-sales Service: | Provided |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 5760/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
100V 120A High Quality Lithium Battery Pack Comprehensive Tester Test Equipment Manufacturer
ACEY-BIT100-10A120A Integrated tester can be used to test Battery open circuit voltage, battery AC internal resistance, continuous charging current, continuous charging voltage, continuous discharging current, continuous discharging voltage, charging overcurrent protection current, discharging overcurrent protection current, short circuit protection time, overcurrent delay time, post-test voltage.
The device uses infrared scan barcode input (SN) to start the test or detects voltage to start the test automatically.
Application:All li-ion battery with the port of CH+ P+ CH- P-
1. Voltage | No-load voltage and Short circuit protection voltage after the test is completed,Range:0-100V |
2. Internal Resistance | ACIR1000hz, Range:0-4000mΩ |
3. Charging overcurrent protection current , Range | 0-10A. |
4. Continuous charging current, Range | 0-10A. |
5. Continuous charging voltage monitoring, Range | 0-100V |
6. Discharge overcurrent protection current and delay time, Rang of current | 0-120A |
7. Continuous discharge current, Range | 0-120A. |
8. Continuous discharge voltage judgment, Range | 0-100V. |
9. Short circuit protection time | ≤1000μ, Max Short circuit current about 5000A |
Voltage range | 0-100V | resolution | 1mV | Accuracy | 0.1%RD+0.1FS |
Internal resistance | 0-2000mΩ resolution | resolution | 0.001mΩ | Accuracy | 0.1%RD+0.1FS |
Charge current | 0-10A resolution | resolution | 0.001A | Accuracy | 0.1%RD+0.1FS |
Discharge current | 0-120A at the highest voltage, continued discharge current 120A | resolution | 0.001A | Accuracy | 1%RD+0.1FS |
Overcurrent delay time | 0-30S resolution | resolution | 1mS | Accuracy | 0.1%RD+0.1FS |
short circuit time | 0-2000μS resolution | resolution | 1μS | Accuracy | 0.1%RD+0.1FS |
NTC range | 0-100K 0.001K | ||||
R1 range | 0-100K 0.001K | ||||
Power supply | AC 200V-240V |
Equipment requirements:
*Equipment operating environment: ventilated and dry plant.
*Working environment: temperature -10ºC~40ºC/humidity: 10%~90%
*Equipment operation mode: upper computer control, manual test.
*The equipment comes with NG alarm device (buzzer)